Kits
Comprise:
Transmitter
Carrying Pouch/Strap
Receiver with rapid-termination spring terminals
2 x batteries (standard or Li-ion as specified)
Charger (specify 10-30Vdc or 110/240Vac)
Aerial (internal/external/extension as specified)
Manuals & Drawings
LKNeo Transmitters
Receivers
TYPE ACRS13-L / ACRS13-G
40-264 VAC
13 relays + STOP + SAFETY
4 x inputs (G version only)
Environmental protection to IP65
-20
O
C to +70
O
C operating
123 x 258 x 83 mm
Internal aerial standard/ External aerial option
TYPE DCRS13
9-30VDC (also 24Vac with internal aerial only)
13 relays + STOP + SAFETY
4 x inputs
Environmental protection to IP65
-20
O
C to +70
O
C operating
123 x 258 x 83 mm
Internal aerial standard/ External aerial option
TYPE MVRCAN
8-30Vdc / 24Vac
Environmental protection to IP65
-20
O
C to +70
O
C operating
144 x 120 x 63 mm
External aerial
4 x Outputs + STOP
CANOpen/ CAN2.0B
TPDOs contain transmitter status
RPDOs can control feedback LEDs on the transmitter
LKNeo6
LKNeo8
LKNeo10
LKNeo12
STANDARD FEATURES
- STOP function up to PLe /SIL 3 (model dependant)
- Rugged fibre-reinforced nylon cases to IP65
- 6, 8, 10, or 12 x 2-speed push-buttons
- Frequency Hopping Spread Spectrum (FHSS) 915-928MHz or
433/915 dual-band Listen-Before-Talk radios (depending on
model)
- Licence-free throughout Australia and New Zealand (LIPD/SRD
Class Licensed)
- Completely automatic frequency management
- Superior operating range in challenging environments
- Stable radio link even for long-range applications (including
tower cranes, concrete pumps)
- 4 x LEDS available to display machine status/operating mode
- Receiver can include logic programming that utilises inputs,
timers, etc.
- More than 8hr per charge (with standard batteries, >16hr with
Li-ion option)
- The installer can program various features:
- PIN code used to start the remote (to prevent
unauthorised use)
- Selectable operating range
- Low-power-start option (requires the operator to
approach the machine when first starting the remote to ensure
that the act is intentional and the correct remote/machine has
been selected)
OPTIONS AVAILABLE
- Additional
toggles
potentiometers
push-buttons
rotary switches
BCD switches
Keyswitches
- Fully customisable full-colour labelling with logos etc.
- External smart ID-key for simple, safe transmitter substitution
- External M-key as an alternative to PIN code for controlling
transmitter access
- Li-ion Batteries for extended operating time (>16hr)
- Multi-Transmitter, Multi-Receiver, Tandem, Master-Slave, Pitch-
Catch systems available.
- Side Enable button for ‘dead-man’ functions with panic feature
- Hold-to-run
- Releasing or depressing further will stop operation
- Infra-red (IR) receiver on the transmitter can be used in various
ways
- Ensure the operator is close to the machine when
starting it
- Require the operator to be in a specific area when
controlling the machine
- Make different functions available to the operator
depending on their location
- Colour graphic screen available in the LKNeoDF type
- Explosion-proof versions available in the LKNexEx type
LKNeo8 with ENABLE button,
toggle switch,
and smart ID-key
TYPE DCRM24
12-24Vdc
Environmental protection to IP65
-20
O
C to +70
O
C operating
185 x 287 x 105 mm
22 x FET outputs + Safety/Flow + STOP
2 x Relay outputs
2 x Expansion slots for
- Additional digital outputs (Total of 40 + Safety +
STOP possible)
- Analogue voltage / PWM outputs
- Analogue / Digital / Loadcell inputs
- Serial RS232/485/ CANBus / CANOpen Interface
- Ethercat , Ethernet/IP, ProfibusDP, Profinet
- ModbusRTU (via IndustryIQ module)
-Synchronising Module (for multiple-receiver co-
ordination of limit-switches, etc)
- Internal / External aerial
- 8 x inputs for for use in logic or Data Feedback LEDs
MODULAR RECEIVERS FOR COMPLEX SYSTEMS
TYPES ACRM5E / MVRL9E/ ACRDIN/ MVRDIN
The above receivers address most common applications, but the AUTEC range also
includes modular receivers with great expandability, sophisticated options, and large I/O
counts.
Our technical team can help choose the best solution for your task.
see also….
TYPE DCRF13
12 / 24 Vdc
8 x FET outputs, 4A
5 x relays + STOP + SAFETY
4 x inputs
Environmental protection to IP65
-20
O
C to +70
O
C operating
150 x 165.5 x 60 mm
External aerial standard
Expansion modules for 2 x PWM or 8 x additional FET outputs
TYPE ACRM15
40-264Vac
Environmental protection to IP65
-20
O
C to +70
O
C operating
185 x 287 x 105 mm
15 x Relays + Safety + STOP
2 x Expansion slots for
- Additional digital outputs (Total of 31 + Safety +
STOP possible)
- Analogue voltage / PWM outputs
- Analogue / Digital / Loadcell inputs
- Serial RS232/485/ CANBus / CANOpen Interface
- Ethercat , Ethernet/IP, ProfibusDP, Profinet
- ModbusRTU (via IndustryIQ module)
-Synchronising Module (for multiple-receiver co-
ordination of limit-switches, etc)
-Internal / External aerial
-4 x inputs for for use in logic or Data Feedback
LED